Part 1: General
1.1 Description of Work
A. Work in this section includes fabrication and installation of extruded aluminum framed overhead canopies as manufactured by Awning Works, Inc.
B. Design Considerations
1. Flashing of various configurations as required by the attachment design approach
2. Determine wall construction and blocking requirements
3. Site Specific Engineering per local codes
4. Direction of water drainage and method
5. Field verification of elevations, dimensions, existing structures, obstructions or materials
1.2 Quality of Assurance
A. Products meeting specifications as established by quality standards, design & manufacturing techniques developed by Awning Works, Inc. Florida 1.866.873.2941, website:www.awningworksinc.com
B. If requested, supply manufacturer's standard literature and specifications for canopies
C. When specified by contract; submit engineered shop drawings showing structural component locations/positions, material dimensions and details of construction assembly
1.3 Field Management
A. Confirm site dimensions prior to manufacturing
1.4 Performance Requirements
A. Canopy must conform to local building codes
B. Determine if specific load requirements have been established for canopies and if stamped calculations are required for location in which canjopy is installed
1.5 Deliver, Storage, Handling
A. Deliver and store all canopy components in protected areas defined by the customer or general contractor. Handle canopy products in a manner that minimizes field touch-up.
Part 2: Products
2.1 Manufacturer
A. Awning Works Inc., www.awningworksinc.com
14115 63rd Way N.
Clearwater Florida 33760
Phone: 1.866.873.2941
Fax: 727-524-3110
Email: awnings@awningworksinc.com
2.2 Materials
A. Perimeter framing (fascia), bracing and diagonal support arms shall be minimum extruded aluminum, alloy 6063-T5, in profile and thickness as determined by the engineering requirements.
B. Inset paneling, sheet or louvers shall be the style, material and thickness as specified on the drawing
C. All attachment hardware shall be rust resistant or stainless steel as specified on the shop drawing
2.3 Finishes
A.Standard mill options are mill, anodized, Pac-Clad, Kynar 500, marine grade powder coat, automotive grade acrylic enamel. Steel panels are available in 20 year Kynar and Galvalume finishes. Roll formed panels are available as stock baked enamel finish in white, bronze or ivory.
2.4 Fabrication
A. All framework connections shall be MIG or TIG welded. Mechanical connections shall be used for panel integration and support members. Locknuts shall be used exclusively.
B. Panels shall be designed as interlocking aluminum members, except for sheet designs and louvers, with mechanical fasteners shop applied wherever possible to provide structural integrity for the completed assembly. Completed sections will be field assembled.
C. Drainage: Water shall drain from covered surfaces to the front edge of the canopy, into integral fascia gutter or directed to the rear for ground level discharge via one or more designed downspouts.
Part 3: Execution
3.1 Execution
A. Confirm that surrounding area is ready for the canopy installation.
B. Installer shall confirm dimensions and elevations to be as shown on drawings provided by Awining Works, Inc.
C. Erection shall be performed by an approved installer and scheduled after all painting, concrete, masonry and roofing in the area is completed
3.2 Installation
A. Installation shall be in strict accordance with manufacturer's shop drawings. Particular attention should be given to protecting the finish during the handling and erection. Field touch up paint will be applied to any marred areas.
3.3 After installation, the work site and canopy will be left in a clear condition.
|